KASON-LI600 Laser interferometer

KASON-LI600 Laser interferometer
KASON-LI600 Laser interferometer
KASON-LI600 Laser interferometer

Product instruction

A universal high-precision laser interferometer specially developed for machine tool inspection and measurement.

Adopts single-frequency laser interferometer with dual longitudinal and transverse thermal stabilization technology.

Compact and well-built, suitable for on-site service and calibration.

Automatic environmental compensation: delivers accurate detection under varying temperature, humidity and pressure conditions.

Intuitive measurement and analysis software that automatically generates measurement data reports and error compensation files, enabling efficient and reliable machine tool inspection under complex working conditions.

Can be combined with different optical components to detect geometric errors such as linearity, angle, straightness, squareness, parallelism and flatness. It is an efficient Calibration tool for high-precision linear displacement measurement, CNC machine tool calibration, Coordinate Measuring Machine calibration and optical platform calibration.

Main Specifications

Item

Specification

Laser Source

HeNe laser

Frequency Stabilization Method

Dual-longitudinal-mode thermal frequency stabilization

Laser Wavelength

632.99 nm (typical)

Laser Power

>0.5 mW

Laser Frequency Stability Accuracy

±0.04 ppm

Measurement Accuracy

±0.5 ppm*

Resolution

1 nm

Measurement Range

0–80 m

Maximum Measurement Speed

4 m/s

Specified Accuracy Range

0°C–40°C

Warm-up Time

<10 min

Main Unit Dimensions

225 mm × 125 mm × 74 mm

Main Unit Weight

2.4 kg

Power Supply

External 100–240 VAC, auto-adaptive

Interface

USB communication port

Trigger Pulse Input

Yes

Dynamic Sampling Frequency

100 kHz

System Measurement Capability

Linear displacement, angle, straightness, squareness, parallelism, flatness, yaw

Sensor

Range

Accuracy

Material Temperature

0°C–50°C

±0.1°C

Air Temperature

0°C–40°C

±0.2°C

Atmospheric Pressure

65–115 kPa

±100 Pa

Relative Humidity

0–95% RH (non-condensing)

±6% RH

Note:The accuracy value excludes the error associated with normalizing the material temperature to 20°C